(268 products available)
HPS lamp ignitor is essential in starting high-pressure sodium lamps. It provides the necessary high-voltage pulse to ignite the lamp and establish an arc. HPS lamps are widely used for outdoor lighting, streetlights, and industrial spaces. Therefore, the ignitor plays a crucial role in the functioning of these lamps. Below are the types:
Internal Ignitor:
Internal ignitors are built directly into the ballast case. They form part of the ballast assembly. As a result, installation is simple. The ignitor is installed as part of the ballast. This ignitor is popular among manufacturers due to its ease of design. However, replacing the internal ignitor may require replacing the entire ballast unit.
External Ignitor:
External ignitors are separate units from the ballast. They are housed in their own casing. This makes it easy to replace in case of failure. Also, the design of the external ignitor is more versatile. It can be used with various types of ballasts. Due to its design, the external ignitor may take more space and require additional wiring.
Solid State Ignitor:
These are modern ignitors. They use semiconductor components instead of mechanical elements. The design makes them more efficient and reliable. Additionally, they have a compact design which makes them lightweight. Also, they provide precise and consistent starting pulses. As a result, they can improve lamp performance and lifespan. Their modern design makes them popular among manufacturers. They can be used with different types of ballasts.
Ignitor Circuit:
This is a traditional approach to ignitor design. It consists of a series of components that work together to produce a high-voltage pulse. The components include a capacitor, a resistor, and a high-voltage switch. The circuit design is reliable. However, it is less efficient compared to solid-state ignitors. Also, it may require more space.
HPS lamp ignitors have different features that provide various functions. Below are some features and functions of HPS lamp ignitors:
High voltage generation
The HPS lamp ignitor is designed to produce a high voltage necessary for igniting or starting the lamp. The high voltage generated creates an arc between the lamp's electrodes, initiating the gas discharge process. This process leads to the ignition of the HPS lamp.
Pulse ignition
The ignitor produces a high voltage in a rapid pulse. Pulsed ignition helps to reduce the amount of heat wasted and enhances the lamp's efficiency. Also, pulse ignition requires less voltage than conventional continuous-wave ignition, making it suitable for igniting HPS lamps.
Cold starts
The HPS lamp ignitor can successfully ignite lamps that are at ambient temperature. Cold starts are useful for lamps that are often turned off and on frequently. Additionally, lamps that have cooled down after being turned off can easily be ignited with an HPS lamp ignitor.
Compatibility
The ignitor is compatible with various types of HPS lamps. It can be used with different wattages. The compatibility feature makes the ignitor versatile and useful in various applications.
Miniature size
HPS lamp ignitor is designed to be compact and small. The miniature size allows for easy integration into different lighting systems. This helps to conserve space and reduce the overall lighting system's weight.
Robust design
The HPS lamp ignitor is designed to be robust and durable. It can be able to withstand harsh environmental conditions. A robust design ensures the ignitor functions optimally for an extended period of time with minimal maintenance.
Overload protection
The HPS lamp ignitor has a protection feature that prevents damage in case of a lamp failure or when there is a short circuit. Overload protection ensures the safety and longevity of the ignitor, making it a reliable choice for users.
There are various hps lamp ignitor scenarios where an HPS lamp ignitor is used, including:
Street Lighting:
High-pressure sodium lamps are often used for street lighting because of their bright orange light that improves visibility. The lamps are also energy-efficient. HPS lamps are suitable for use in large areas like streets since they require an ignitor to operate.
Industrial Lighting:
Workplaces like factories and warehouses use HPS lamps for lighting. HPS lamps are perfect for these spaces since they provide a lot of light and are energy-saving. The use of HPS lamps in industrial spaces improves productivity and safety.
Sports Facilities:
High-pressure sodium lamps are used in sports facilities like stadiums, courts, and fields. The lamps need an HPS lamp ignitor to provide bright lighting in large areas. HPS lamps are good for sports facilities since they are energy-saving and provide high-intensity lighting.
Commercial Lighting:
HPS lamps are used for lighting in commercial spaces like parking lots, malls, and gas stations. The lamps provide adequate lighting for large commercial spaces. An HPS lamp ignitor is also needed for these applications to ensure the lamps operate efficiently.
Agricultural Lighting:
High-pressure sodium lamps are used in agricultural settings like greenhouses to promote plant growth. The lamps provide the right light spectrum for plants to grow efficiently. An HPS lamp ignitor is necessary for the lamps to function.
Security Lighting:
High-pressure sodium lamps are used for security lighting in residential and commercial spaces. The lamps need an HPS lamp ignitor to provide bright lighting that prevents trespassing and vandalism. HPS lamps are good for security lighting since they are energy-saving and provide bright orange light.
When choosing an HPS lamp ignitor, there are several factors to consider to ensure compatibility, reliability, and efficiency. Here are some key elements to take into account:
Wattage Compatibility
Different types of HPS lamps come with various power ratings. It is important to select an ignitor that is compatible with the specific wattage of the lamps to be used. An ignitor that is not compatible with the lamp's wattage may result in failure to ignite or damage to the lamp.
Electrode Configuration
Some lamps are equipped with different electrode configurations. Choose an ignitor that is compatible with the lamp's electrode configuration. This ensures efficient ignition and prevents misfires.
Reliability and Brand Reputation
Consider choosing ignitors from reputable manufacturers known for producing reliable and high-quality products. Read reviews and testimonials to get insight into the performance and longevity of the ignitors.
Build Quality and Components
Examine the build quality of the ignitor. Choose an ignitor constructed with high-quality components that are able to withstand high temperatures and harsh environments. Good build quality ensures the reliability and longevity of the ignitor.
Customer Support and Warranty
When purchasing HPS lamp ignitors in bulk, it is important to consider the availability of customer support and warranty options. A good warranty will cover any defects and provide replacements at no cost. Reliable customer support is important when there is a need for technical assistance or to address any issues.
Ease of Installation
Consider selecting ignitors that come with easy-to-follow installation instructions. An ignitor that is simple to install will save on installation costs and time.
Q1: What are HPS lamps used for?
A1: High-pressure sodium lamps are commonly used for street lighting, parking lots, security lighting, industrial lighting, and outdoor area lighting. They are also used in horticulture to promote flowering and fruiting in plants.
Q2: What are the disadvantages of HPS lamps?
A2: HPS lamps have several disadvantages, such as producing light with a yellowish-orange color. This is not ideal for applications requiring color accuracy, and it can lead to color distortion. Additionally, these lamps have a longer warm-up time than other options, a high humidity requirement, and a low CRI.
Q3: What are the three types of ignitors?
A3: There are three types of ignitors: solid-state ignitors, capacitor discharge ignitors, and RF ignitors.
Q4: How can one identify a faulty ignitor?
A4: Some signs of a faulty ignitor include a delay in lamp striking, flickering or unstable light output, and frequent starting failures. In some cases, the ignitor may cause an HPS lamp to flicker or extinguish.